1.
Cancer Imaging ; 16: 6, 2016 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-27052371

RESUMO

BACKGROUND: We hypothesized that indocyanine green (ICG) fluorescence patterns using Clairvivo OPT in resected liver specimens could confirm hepatocellular carcinoma (HCC) better than earlier commercial imaging systems. This preclinical trial evaluated the effectiveness of fluorescence imaging as an intraoperative cancer navigation tool. METHODS: ICG fluorescence images of resected specimens from 190 patients with HCC were classified into two groups according to whether high fluorescence was seen in the HCC (high cancerous [HC] group) or in the surrounding liver tissue (high surrounding [HS] group). The HC and HS groups were sub-classified into whole and partial types and whole and ring types, respectively. RESULTS: The HC group had significantly higher prevalence of esophageal or gastric varices, and worse liver function than patients in the HS group. The HC group also had a higher percentage of limited resection cases than did the HS group. Cirrhotic liver histology was significantly more common in the HC group than in the HS group. Multivariate analysis revealed that the HC group was a predictive factor for cirrhosis in HCC patients. Among the HC patients, a higher percentage of well-differentiated HCC cases were seen in the partial-type subgroup than in the whole-type subgroup (23/48 (48 %) vs. 7/68 (10 %)). In the HS group, the ring-type subgroup had a higher percentage of poorly differentiated HCC cases than did the whole-type subgroup (6/37 (16 %) vs. 0/37 (0 %)). CONCLUSION: Tumor differentiation and fibrosis in the non-cancerous liver parenchyma could affect ICG fluorescence imaging in HCC. ICG fluorescence imaging may be a good indication for fibrosis stage. In future, we will try to evaluate fluorescence imaging with ICG for intraoperative cancer navigation in HCC, using a portable near-infrared fluorescence imaging system.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Corantes , Verde de Indocianina , Neoplasias Hepáticas/diagnóstico , Imagem Óptica/métodos , Administração Intravenosa , Idoso , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Corantes/administração & dosagem , Varizes Esofágicas e Gástricas/diagnóstico , Varizes Esofágicas e Gástricas/patologia , Feminino , Hepatectomia/métodos , Humanos , Verde de Indocianina/administração & dosagem , Raios Infravermelhos , Cuidados Intraoperatórios , Lasers Semicondutores , Fígado/patologia , Cirrose Hepática/diagnóstico , Cirrose Hepática/patologia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Masculino , Microscopia de Fluorescência/instrumentação , Pessoa de Meia-Idade , Imagem Óptica/instrumentação , Estudos Retrospectivos , Fatores Sexuais
2.
World J Surg Oncol ; 13: 198, 2015 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-26055754

RESUMO

BACKGROUND: Reports detailing microscopic observations of indocyanine green (ICG) fluorescence imaging (IFI) in hepatocellular carcinoma (HCC) and metastatic liver cancer are rare. We were able to perform macro- and microscopic IFI results in postoperative paraffin-embedded tissue samples and formalin-fixed specimens from liver tumors. METHODS: Between April 2010 and March 2014, 19 patients with HCC or liver metastases of colorectal tumors underwent liver resection. ICG solution was injected into the peripheral vein from 14 to 2 days prior to operation. We observed liver tumor IFI during the laparotomy and IFI in resected liver sections using a photo dynamic emission (PDE) camera. The IFI of paraffin-embedded tissue samples was observed using a charge-coupled device (CCD) camera. Moreover, we microscopically performed tissue section IFI using a fluorescence microscope with an ICG-B-NQF. RESULTS: We performed that IFI characteristics depended on tumor type macroscopically and microscopically. In normal liver tissue, fluorescence consistent with the bile canaliculus was observed. HCC had heterogeneous IFI, forming a total or partial tumor and rim pattern. In metastatic carcinoma, we performed that non-tumor cells in the marginal region showed fluorescence and tumor cells in the central region did not fluoresce. CONCLUSIONS: We confirmed that the variations of ICG fluorescence imaging patterns reflect different tumor characteristics in not only macroscopic imaging as previous reports but also microscopic imaging. Moreover, the ICG fluorescence method is useful for postoperative pathological detection of microscopic lesions in histopathological specimens. ICG fluorescence in paraffin-embedded tissue samples and formalin-fixed specimens is preserved in the long term.


Assuntos
Carcinoma Hepatocelular/patologia , Corantes , Verde de Indocianina , Neoplasias Hepáticas/patologia , Humanos , Microscopia de Fluorescência , Inclusão em Parafina
3.
Pediatr Surg Int ; 31(4): 407-11, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25667048

RESUMO

To achieve precise and sensitive detection of chemotherapy-resistant hepatoblastoma pulmonary metastases, we performed surgery using indocyanine green (ICG) fluorescence imaging navigation. Lung metastasectomies were performed in 10 patients aged from 1 to 11 years. ICG (0.5 mg/kg) was injected intravenously 24 h before the operation. After a thoracotomy had been performed, a 760-nm infrared ray was applied to the lung using a generator and the 830-nm evoked fluorescence was collected and visualized on a real-time display. In total, 250 fluorescence-positive lesions were extirpated in 37 operations. All of the pathologically positive lesions were clearly fluorescence positive. The diameter of the smallest detectable lesion was 0.062 mm. In two patients, there were 29 extirpated lesions that were pathologically proven not to be hepatoblastoma metastases. Although a problem of false positive remains, this method is very useful for the detection of small pulmonary metastases.


Assuntos
Diagnóstico por Imagem/métodos , Hepatoblastoma/cirurgia , Verde de Indocianina , Neoplasias Hepáticas/patologia , Neoplasias Pulmonares/cirurgia , Pneumonectomia/métodos , Cirurgia Assistida por Computador/métodos , Criança , Pré-Escolar , Corantes , Hepatoblastoma/diagnóstico , Hepatoblastoma/secundário , Humanos , Lactente , Neoplasias Hepáticas/cirurgia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/secundário , Estudos Retrospectivos
4.
J Neurosurg Spine ; 19(5): 624-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24053371

RESUMO

Superior cluneal nerve (SCN) entrapment neuropathy is a known cause of low back pain. Although surgical release at the entrapment point of the osteofibrous orifice is effective, intraoperative identification of the thin SCN in thick fat tissue and confirmation of sufficient decompression are difficult. Intraoperative indocyanine green video angiography (ICG-VA) is simple, clearly demonstrates the vascular flow dynamics, and provides real-time information on vascular patency and flow. The peripheral nerve is supplied from epineurial vessels around the nerve (vasa nervorum), and the authors now present the first ICG-VA documentation of the technique and usefulness of peripheral nerve neurolysis surgery to treat SCN entrapment neuropathy in 16 locally anesthetized patients. Clinical outcomes were assessed with the Roland-Morris Disability Questionnaire before surgery and at the latest follow-up after surgery. Indocyanine green video angiography was useful for identifying the SCN in fat tissue. It showed that the SCN penetrated and was entrapped by the thoracolumbar fascia through the orifice just before crossing over the iliac crest in all patients. The SCN was decompressed by dissection of the fascia from the orifice. Indocyanine green video angiography visualized the SCN and its termination at the entrapment point. After sufficient decompression, the SCN was clearly visualized on ICG-VA images. Low back pain improved significantly, from a preoperative Roland-Morris Questionnaire score of 13.8 to a postoperative score of 1.3 at the last follow-up visit (p < 0.05). The authors suggest that ICG-VA is useful for the inspection of peripheral nerves such as the SCN and helps to identify the SCN and to confirm sufficient decompression at surgery for SCN entrapment.


Assuntos
Cineangiografia/normas , Descompressão Cirúrgica/normas , Plexo Lombossacral/diagnóstico por imagem , Monitorização Intraoperatória/normas , Síndromes de Compressão Nervosa/diagnóstico por imagem , Adulto , Cineangiografia/instrumentação , Corantes , Descompressão Cirúrgica/instrumentação , Descompressão Cirúrgica/métodos , Feminino , Humanos , Verde de Indocianina , Dor Lombar/etiologia , Dor Lombar/cirurgia , Plexo Lombossacral/patologia , Plexo Lombossacral/cirurgia , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Bloqueio Nervoso/métodos , Síndromes de Compressão Nervosa/complicações , Síndromes de Compressão Nervosa/cirurgia , Inquéritos e Questionários , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...